Mkube Buy Digital & Automatic Melting Point Apparatus
Automatic Melting Point Apparatus

Melting Point Apparatus (MP420/MP430 and MP450/MP470/MP490 Models)

Inquiry Now

Product Description

The Melting Point Apparatus is a precision laboratory instrument designed for accurate determination of melting points of solid substances. Widely used in pharmaceuticals, chemicals, academic research, and quality control laboratories, a melting point test is a critical parameter for material identification, purity analysis, and quality assurance.

M-Kube offers a complete range of automatic melting point apparatus and digital melting point apparatus models, including MP420, MP430, MP450, MP470, and MP490, catering to different laboratory requirements across India. These advanced melting point measuring instruments deliver high accuracy, repeatability, and user-friendly operation at a competitive melting point apparatus price.

Key Features of Digital Melting Point Apparatus

  • Fully automatic melting point measurement
  • High-precision digital melting point apparatus with optical detection
  • Clear LCD / touchscreen display
  • Accurate and repeatable temperature control
  • Simultaneous testing of multiple samples
  • Adjustable heating rates for different standards
  • Automatic start, stop, and result recording
  • Compact, robust, and laboratory-friendly design
  • Compliant with pharmacopoeial standards

Typical Technical Specifications

Specification MP420 MP430 MP450 MP470 MP490
Capillary position capacity                                                           4                                                           4                                                           4                                                           4                                                           4
Capillary size                                                 inner 0.9 ~ 1.1 mm inner 0.9 ~ 1.1 mm inner 0.9 ~ 1.1 mm inner 0.9 ~ 1.1 mm inner 0.9 ~ 1.1 mm
Magnification of lens                                                         8 8 8 8 8
Display Color 8-inch Touch Screen Color 8-inch Touch Screen Color 8-inch Touch Screen Color 8-inch Touch Screen Color 8-inch Touch Screen
Temperature range RT-300℃                         RT-350℃  RT-350℃ RT-400℃ RT-400℃
Temperature accuracy                                             0.4 at 200℃; 0.7 at 300℃   

 0.4 at 200℃; 0.7 at 300℃

   

0.4 at 200℃; 0.7 at 300℃

   

0.4 at 200℃; 0.7 at 300℃

  

 0.4 at 200℃; 0.7 at 300℃

Temperature resolution                                                       0.1℃ 0.1℃ 0.1℃ 0.1℃ 0.01℃
Temperature repeatability                                                       0.2℃   

 0.2℃

   

0.2℃

  

 0.2℃

   

0.2℃

Temperature gradients                                                     0.1℃-20℃    

0.1℃-20℃

  

 0.1℃-20℃

  

 0.1℃-20℃

   

0.1℃-20℃

Video & Camera Camera                       Video & Camera Video & Camera Video & Camera Video & Camera
Video reply No               

         Yes

        

Yes

         

Yes

         

Yes

Automatic find melting point               Manual Manual                 Automatic Automatic Automatic
Room capacity 8 GB 16 GB 16 GB 32 GB 128 GB
Graphic 0 0 100 200 500
Methods storage 10 30 30 80 200
Communication ports                       USB x3, RS232, Wi-Fi, RJ45 USB x3, RS232, Wi-Fi, RJ45 USB x3, RS232, Wi-Fi, RJ45 USB x3, RS232, Wi-Fi, RJ45 USB x3, RS232, Wi-Fi, RJ45
Printer Thermal printer                   Laser printer/ Thermal printer  

Laser printer/ Thermal printer

 

Laser printer/ Thermal printer

 Laser printer/ Thermal printer
ID management No 20 20 30 100
User classify No Yes Yes Yes Yes
Data provenance No Yes No Yes Yes
FDA 21 CFR part11 No Yes  No Yes Yes

 

Applications of Melting Point Apparatus

  • Pharmaceutical quality control
  • Chemical industry & material identification
  • Academic & research laboratories
  • Food and fine chemical testing
  • Purity determination of organic compounds
  • R&D and formulation laboratories

Explore related analytical instruments from M-Kube:

Quality and Compliance

All M-Kube melting point apparatus models are manufactured in ISO-certified facilities and tested in accordance with relevant pharmacopoeial and international laboratory standards. Each melting point measuring instrument is validated for temperature accuracy, repeatability, and long-term reliability.

Why Choose M-Kube for Melting Point Instruments?

  • Competitive melting point apparatus price
  • Wide range from manual to fully automatic melting point apparatus
  • High accuracy with reliable digital detection
  • Strong after-sales service and technical support
  • Suitable for QC, R&D, and regulated laboratories

Get a Quote

Looking for a reliable melting point apparatus, digital melting point instrument, or automatic melting point apparatus for your laboratory?

📞 Call: +91 9898892994
📧 Email: marketing@mkubeenterprise.co.in 

Product FAQ's

How does an automatic melting point apparatus ensure accuracy?

The automatic melting point apparatus uses precision sensors and controlled heating rates to maintain consistent temperature measurement accuracy.

What calibration method is used in a digital melting point apparatus?

Most digital melting point apparatus models are factory-calibrated but can also be verified using certified reference materials to ensure reliable readings.

Can a melting point apparatus measure multiple samples simultaneously?

Yes, advanced melting point instruments can analyze multiple capillary tubes at once, improving productivity and comparison consistency.

How fast does the melting point equipment heat up?

The melting point equipment typically features adjustable heating rates ranging from 0.1°C/min to 20°C/min, allowing controlled temperature ramping.

What type of display and control system does a digital melting point apparatus use?

Modern digital melting point apparatus units include high-resolution LCD or touch displays with intuitive interfaces for temperature setting and monitoring.

How is data recorded in an automatic melting point apparatus?

The melting point measuring instrument automatically records temperature data and can export results via USB or internal memory for documentation.

What kind of samples can be tested using aluminum capillary tubes?

The melting point equipment supports a wide range of organic and inorganic compounds, provided they are stable under controlled heating.

How does the instrument handle temperature uniformity?

The automatic melting point apparatus maintains even temperature distribution using advanced microprocessor controls and uniform heating blocks.

What kind of temperature range can be handled by M-Kube Melting point apparatus?

The automatic melting point apparatus comes in various configurations and can handle temperatures upto 400°C. You can contact M-Kube for more details about the various configurations.

What is difference between Slip Melting point and Automatic melting point apparatus? Is there a 2 in 1 model available?

Both, Slip Melting point and automatic melting point apparatus operate on different working principles for different applications. A 2-in-1 model is not possible. Slip melting point apparatus is mainly used for wax kind of products.